  1. Novell UPS.NLM does not support UPS monitoring via the serial port.
  2. Your options are summarized in the following "Table of Contents."
  3.  
  4. 1 - SS keycard with UPS monitoring
  5. 2 - Disk coprocessor board (37 pin version) DCB
  6. 3 - Novell UPS monitoring board
  7. 4 - PS/2 compatible mouse port
  8. 5 - Third Party Software for Serial Port Monitoring 
  9.  
  10.  
  11. 1 - SS keycard with UPS monitoring
  12. ----------------------------------
  13. Jumper 1 (JMP1): 
  14.     set to the S2 position, indicating that closed contacts
  15.     will signify a Low Battery condition.
  16.  
  17. Jumper 5 (JMP5):
  18.     set to the S10 position, indication that closed contacts
  19.     will signify an Inverter On condition.
  20.  
  21. All other jumpers should remain in their default positions. For more 
  22. information, refer to the "Novell SFT/Advanced Netware 286 Manual,"
  23. page 2-22, or the appropriate Netware 386 manual.
  24.  
  25.  
  26. 2 - Disk coprocessor board (37 pin version) DCB
  27. -----------------------------------------------
  28. Select jumper position S-18 indicating that closed 
  29. contacts will signify a Low Battery condition.
  30.  
  31. Select jumper position S-19 indicating that closed
  32. contacts will signify an Inverter On condition.
  33.  
  34. For more information, refer to the "Novell SFT/Advanced Netware 
  35. 286 Manual," page 2-32, "Checking the I/O Address of a Disk
  36. Coprocessor Board," or the appropriate Netware 386 manual.
  37.  
  38.  
  39. 3 - Novell UPS monitoring board
  40. -------------------------------
  41. Jumper 1 (JMP1): 
  42.     set to the S2 position, indicating that closed contacts
  43.     will signify a Low Battery condition.
  44.  
  45. Jumper 2 (JMP2):
  46.     set to the S3 position, indicating that closed contacts
  47.     will signify an Inverter On condition.
  48.  
  49. For more information, refer to the "Novell SFT/Advanced Netware 
  50. 286 Manual," page 2-37, "Setting the UPS I/O address," or the 
  51. appropriate Netware 386 manual.
  52.  
  53.  
  54. 4 - PS/2 compatible mouse port
  55. ------------------------------
  56. mouseport pinouts:
  57.  
  58.     Pin #      Description
  59.     ------     ---------------------
  60.        1 ----- On-AC Comercial Power
  61.        2 ----- Not Used
  62.           3 ----- Ground
  63.           4 ----- Not used
  64.           5 ----- Low-Battery-Warning signal 
  65.           6 ----- Not Used
  66.  
  67. Pins 1 & 3 of the mouse port connect to normally closed contacts
  68. on the UPS. A relay opening will signify an Inverter On conditon.
  69.  
  70. Pins 5 & 3 of the mouse port connect to normally open contacts
  71. on the UPS. A relay closing will signify a Low Battery condition.
  72.  
  73. looking at the mouse port:
  74.  
  75.       -------- 
  76.      / 6 ## 5 \                     
  77.     | 4      3 |
  78.      \ 2    1 /
  79.       --------         
  80. (the ## is the Notch in the connector)
  81.  
  82.  
  83.  
  84. 5 - Third Party Software for Serial Port Monitoring 
  85. ---------------------------------------------------
  86. If you *must* use the serial port, then you'll need a third party 
  87. UPS monitor software package. Deltec, Topaz, Toshiba, Exide, IPM, 
  88. Sola, and many other UPS vendors use PowerMon Software.
  89. Best can use PowerMon, but you'll get advanced functions 
  90. by using Best's "CheckUPS/II." 
  91.  
  92.     PowerMon Software
  93.     SEC - Systems Enhancement Corp.
  94.     Chesterfield, MO
  95.     314-532-2855
  96.  
  97. PowerMon is a very simple implementation of relay monitoring. The relays
  98. change status of the COM port, and PowerMon interprets these signals as
  99. triggers for messages and shutdown scripts. 
  100.  
  101. If you want interactive UPS monitoring, diagnostics, charts and graphs, and
  102. so on, move up to CheckUPS/II NLM.  CheckUPS/II goes beyong simple relays,
  103. and uses a fully asyncronous interface with the UPS to read the actual
  104. voltage, current, runtime, etc. CheckUPS/II for Novell is a complete 
  105. client/server power management package, and unique in the industry.
  106. Download BEST04.TXT and BEST04.PCX from NOVLIB for more information.
  107.  
  108. Corporate Computing says that "Best's CheckUPS is a superior package
  109. on all grounds." (Nov. 1992, pg. 129) 
  110.  
  111.  
  112.  --------------------------------------------------------------
  113. | Dan Ader - Best Power Technology | Environmental Engineering | 
  114. |--------------------------------------------------------------|
  115. |  ader@macc.wisc.edu | CompuServe 70571,420@ | 800-356-5794   |
  116.  -------------------------------------------------------------- 
  117.